Abdom Radiol (NY) ; 44(12): 4011-4021, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31696266

RESUMO

PURPOSE: To assess the agreement of one-dimensional transient elastography (1D-TE), two-dimensional shear wave elastography (2D-SWE), and magnetic resonance elastography (MRE) in a consecutive cohort of patients affected by hepatitis C virus (HCV) and to understand which patient-related factors are associated with disagreement. METHODS: Ninety-one consecutive patients with current or previous chronic HCV infection were enrolled between March 2017 and September 2018. We assessed the correlation between stiffness measurements expressed in kilopascals (kPa). After converting kPa values in three groups of increasing fibrosis burden using validated cut-off values, we assessed the agreement among the different techniques. Factors influencing inter-modality disagreement were examined by employing multivariate logistic regression analysis. RESULTS: Seventy-seven patients met the inclusion criteria and had reliable measurements by all stiffness imaging techniques. At the quantitative analysis, a strong correlation between stiffness measurements was found (Spearman's rho values ranging from 0.7 to 0.89 in all pairs of techniques). Complete concordance among MRE, 1D-TE, and 2D-SWE was found in 64.9% of patients, and the agreement was highest between MRE and 1D-TE, with κ value of 0.801. In only 2/77 patients (2.6%), there was complete disagreement. High body mass index (BMI) was the only factor significantly associated with inter-modality discordance. CONCLUSIONS: MRE, 1D-TE, and 2D-SWE assigned the majority of patients to the same fibrosis group. The agreement was at least good, and there was a strong correlation between kPa values in all three pairs of techniques. Highest agreement was found between MRE and 1D-TE. High BMI was associated with discordance among the techniques.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite C Crônica/diagnóstico por imagem , Hepatite C Crônica/virologia , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
2.
Acta Radiol ; 59(5): 540-545, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28862025

RESUMO

Background Magnetic resonance (MR) permits the detection of some malignant lesions that cannot be identified with mammography or ultrasonography. The characterization of these MR-only detectable lesions often requires a biopsy. Purpose To evaluate the technique, the feasibility and the accuracy of freehand 3T MR-guided VAB for the characterization of suspicious, MR-only detectable lesions and to compare VAB results with surgical pathology and follow-up imaging results. Material and Methods During 2010-2015, 118 women who were referred for MR-guided VAB were retrospectively reviewed. All BI-RADS MR 4 and 5 lesions and some BI-RADS MR 3 lesions (according to clinical context and patient anxiety) were scheduled to undergo biopsy. Results A total of 123 suspicious lesions were retrospectively selected. Technical failures occurred in only two cases (1.6%) due to the location of the lesions. Histopathological results revealed 59 benign lesions (48%), 27 high-risk lesions (22%), and 35 malignant lesions (28.4%). Surgical pathology results led to the reclassification of eight B3 lesions: one proved to be a ductal carcinoma in situ, while seven presented with invasive features. B3 underestimation also occurred in 29% of the cases. MR follow-up was achieved for all the benign lesions and no false-negative cases were observed. No complications, 3T-related artefacts, or difficulties were observed. Conclusion Freehand 3T MR-guided VAB was found to be a valid, safe, fast, and inexpensive alternative to surgical histology.


Assuntos
Neoplasias da Mama/patologia , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Vácuo
3.
Radiol Med ; 121(10): 751-62, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27334009

RESUMO

PURPOSE: In magnetic resonance imaging (MRI) relaxometry, various software programs are available to perform R2* measurements and to estimate the liver iron concentration (LIC). The main objective of our study was to compare R2* LIC values, obtained with three different software programs based on specific decay models and calibration curves, with LIC estimates provided by R2-relaxometry (FerriScan). METHODS: This retrospective study included 15 patients with 15 baseline MRIs and 34 serial examinations. R2* LIC estimates were calculated using the FuncTool, CMRtools/Thalassemia Tools and Quanta Hematology programs. Longitudinal LIC changes (ΔLIC) were calculated using the subset of 34 serial MRIs. RESULTS: After Bland-Altman analysis on baseline data, Quanta Hematology, which employs the monoexponential-plus-constant fit, produced the lowest mean difference [0.01 ± 0.14 log(mg/gdw)] with the closest limits of agreement. In the longitudinal setting, Quanta Hematology again gave the lowest mean difference between R2 and R2* LIC (0.1 ± 2.6 mg/gdw). Using FerriScan as reference, the value of concordant directional ΔLIC changes was the same for all programs (27/34, 85.7 %). CONCLUSIONS: R2* LICs are higher than R2 LICs at iron levels <7 mg/gdw, while R2 LIC averages higher than R2* LIC with increasing iron load. The monoexponential-plus-constant model provided the best agreement with R2 LIC estimates.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Sobrecarga de Ferro/diagnóstico por imagem , Ferro/análise , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Software , Talassemia/diagnóstico por imagem , Adolescente , Adulto , Biópsia , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Clin Imaging ; 40(3): 425-30, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27133680

RESUMO

PURPOSE: Compare colonic distension using CT colonography (CTC) and CT with water enema (CTWE) in the same patients. METHODS AND MATERIALS: Twenty-seven patients who underwent both CTC and CTWE, considering separately supine (CTC-S) and prone (CTC-P) acquisition of CTC were included. The colon was divided into six segments, performing both a qualitative and quantitative analysis. RESULTS: Adequate distension of sigmoid colon was more frequently achieved with CTC-P and CTWE compared to CTC-S (P<.05). CTC-P and CTWE showed better distension of the left colon compared to CTC-S (P<.01 and P=.03 regarding sigmoid colon, respectively; P=.01 and P=.03 regarding descending colon, respectively). CONCLUSIONS: Computed tomography (CT) studies of the colon should be customized to fulfill the clinical query.


Assuntos
Colo , Colonografia Tomográfica Computadorizada/métodos , Enema , Decúbito Ventral , Decúbito Dorsal , Água , Adulto , Idoso , Idoso de 80 Anos ou mais , Colo Sigmoide , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Biomed Res Int ; 2015: 758164, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25866807

RESUMO

OBJECTIVE: To assess the diagnostic performance of a T1-independent, T2*-corrected multiecho magnetic resonance imaging (MRI) technique for the quantification of hepatic steatosis in a cohort of patients affected by chronic viral C hepatitis, using liver biopsy as gold standard. METHODS: Eighty-one untreated patients with chronic viral C hepatitis were prospectively enrolled. All included patients underwent MRI, transient elastography, and liver biopsy within a time interval <10 days. RESULTS: Our cohort of 77 patients included 43/77 (55.8%) males and 34/77 (44.2%) females with a mean age of 51.31 ± 11.27 (18-81) years. The median MRI PDFF showed a strong correlation with the histological fat fraction (FF) (r = 0.754, 95% CI 0.637 to 0.836, P < 0.0001), and the correlation was influenced by neither the liver stiffness nor the T2* decay. The median MRI PDFF result was significantly lower in the F4 subgroup (P < 0.05). The diagnostic accuracy of MRI PDFF evaluated by AUC-ROC analysis was 0.926 (95% CI 0.843 to 0.973) for S ≥ 1 and 0.929 (95% CI 0.847 to 0.975) for S = 2. CONCLUSIONS: Our MRI technique of PDFF estimation allowed discriminating with a good diagnostic accuracy between different grades of hepatic steatosis.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Hepatite C Crônica/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fígado Gorduroso/patologia , Feminino , Hepacivirus/patogenicidade , Hepatite C Crônica/patologia , Hepatite C Crônica/virologia , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Prótons , Radiografia
6.
Abdom Imaging ; 40(6): 1772-87, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25579170

RESUMO

Between 27% and 53% of all patients who undergo radical prostatectomy (RP) or radiation therapy (RT) as the first-line treatment of prostate cancer (PCa) develop a biochemical recurrence. Imaging plays a pivotal role in restaging by helping to distinguish between local relapse and metastatic disease (i.e., lymph-node and skeletal metastases). At present, the most promising tools for assessing PCa patients with biochemical recurrence are multiparametric magnetic resonance imaging (mpMRI) and positron emission tomography (PET)/computed tomography (CT) with radio-labeled choline derivatives. The main advantage of mpMRI is its high diagnostic accuracy in detecting local recurrence, while choline-PET/CT is able to identify lymph-node metastases when they are not suspicious on morphological imaging. The most recent advances in the field of fusion imaging have shown that multimodal co-registration, synchronized navigation, and combined interpretation are more valuable than the individual; separate assessment offered by different diagnostic techniques. The objective of the present essay was to describe the value of bimodal choline-PET/mpMRI fusion imaging and trimodal choline-PET/mpMRI/transrectal ultrasound (TRUS) in the assessment of PCa recurrence after RP and RT. Bimodal choline-PET/mpMRI fusion imaging allows morphological, functional, and metabolic information to be combined, thereby overcoming the limitations of each separate imaging modality. In addition, trimodal real-time choline-PET/mpMRI/TRUS fusion imaging may be useful for the planning and real-time guidance of biopsy procedures in order to obtain histological confirmation of the local recurrence.


Assuntos
Recidiva Local de Neoplasia/diagnóstico , Neoplasias da Próstata/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Colina , Diagnóstico por Computador , Radioisótopos de Flúor , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Imagem Multimodal , Recidiva Local de Neoplasia/diagnóstico por imagem , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Prostatectomia , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Compostos Radiofarmacêuticos , Ultrassonografia
7.
Ultrasound Med Biol ; 40(9): 1923-33, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24972497

RESUMO

Despite its invasiveness, liver biopsy is still considered the gold standard for the assessment of hepatic fibrosis. Non-invasive ultrasound-based techniques are increasingly employed to assess parenchymal stiffness and the progression of chronic diffuse liver diseases. Real-time elastography is a rapidly evolving technique that can reveal the elastic properties of tissues. This review examines qualitative and semi-quantitative methods developed for analysis of real-time liver elastograms, to estimate parenchymal stiffness and, indirectly, the stage of fibrosis. Qualitative analysis is the most immediate approach for elastogram analysis, but this method increases intra- and inter-observer variability, which is seen as a major limitation of real-time elastography. Semi-quantitative methods include analysis of the histogram derived from color-coded maps, as well as calculation of the elastic ratio and fibrosis index.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Processamento de Imagem Assistida por Computador/métodos , Cirrose Hepática/diagnóstico por imagem , Sistemas Computacionais , Humanos , Fígado/diagnóstico por imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Abdom Imaging ; 39(5): 1102-13, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24777592

RESUMO

Positron emission tomography (PET) is a functional imaging technique that can investigate the metabolic characteristics of tissues. Currently, PET images are acquired and co-registered with a computed tomography (CT) scan (PET-CT), which is employed for correction of attenuation and anatomical localization. In spite of the high negative predictive value of PET, false-positive results may occur; indeed, Fluorine 18 ((18)F)-fluorodeoxyglucose ((18)F-FDG) uptake is not specific to cancer. As (18)F-FDG uptake may also be seen in non-malignant infectious or inflammatory processes, FDG-avid lesions may necessitate biopsy to confirm or rule out malignancy. However, some PET-positive lesions may have little or no correlative ultrasound (US) and/or CT findings (i.e., low conspicuity on morphological imaging). Since it is not possible to perform biopsy under PET guidance alone, owing to intrinsic technical limitations, PET information has to be integrated into a CT- or US-guided biopsy procedure (multimodal US/PET-CT fusion imaging). The purpose of this pictorial essay is to describe the technique of multimodal imaging fusion between real-time US and PET/CT, and to provide an overview of the clinical settings in which this multimodal integration may be useful in guiding biopsy procedures in PET-positive abdominal lesions.


Assuntos
Abdome/patologia , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Abdome/diagnóstico por imagem , Biópsia , Humanos , Biópsia Guiada por Imagem/métodos , Radiografia Abdominal/métodos
9.
Eur J Radiol ; 82(12): e755-61, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24050879

RESUMO

OBJECTIVE: The objective of our prospective monocentric work was to determine the diagnostic value of real-time elastography (RTE) in the assessment of liver fibrosis in patients with iron overload, using transient elastography (TE) as reference standard. METHODS: Sixty-seven consecutive patients with MRI detectable iron overload (T2*<6.3 ms) were enrolled. TE and RTE were performed on the same day as MRI. Elastograms were acquired by an experienced operator and analyzed by calculating the elastic ratio between perihepatic soft tissues and liver parenchyma. An elliptical ROI of 1cm(2) (Z1) was positioned in the liver parenchyma and a smaller elliptical ROI of 2mm(2) (Z2) was positioned in a homogeneously soft (red) region of the diaphragm, which was considered as internal control to calculate the elastic ratio Z2/Z1. RESULTS: Seven patients were excluded because of invalid TE or RTE examinations. The remaining 60 patients were 57% males and 43% females (mean age: 42 [21-76] years), including 37 homozygous-ß-thalassemics, 13 patients with ß-thalassemia intermedia, 6 with primary hemochromatosis, and 4 with myelodysplastic syndrome. Increasing elastic ratios were significantly correlated with increasing TE values (r=0.645, 95% CI 0.468-0.772, P<0.0001). The mean elastic ratios for each METAVIR group were as follows: F0/1 = 1.9 ± 0.4; F2 = 2.2 ± 0.4; F3 = 2.9 ± 0.5; F4 = 3.2 ± 0.4. The diagnostic accuracy of RTE for F ≥ 2 evaluated by AUC-ROC analysis was 0.798 (95% CI 0.674-0.890). The diagnostic accuracy of RTE for F ≥ 3 was 0.909 (95% CI 0.806-0.968). At a cut-off ≥ 2.75, RTE showed a sensitivity of 70% (95% CI 45.7-88.1) and a specificity of 97.5% (95% CI 86.8-99.9). CONCLUSIONS: In patients with MRI-detectable liver iron-overload RTE allows to discriminate between F0/1-F2 and F3-F4 with a reasonable diagnostic accuracy.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Sobrecarga de Ferro/complicações , Sobrecarga de Ferro/diagnóstico por imagem , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Adulto , Idoso , Sistemas Computacionais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Clin Imaging ; 37(4): 794-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23768742

RESUMO

We report a case of a primary signet ring cell carcinoma (PSRCC) of the small bowel in a patient with long-standing Crohn's disease, describing computed tomography (CT)-enterography (CTE) and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT features of this rare tumor. CTE demonstrated submucosal thickening of a long ileal segment with preserved mural stratification. PET/CT examination showed increased 18F-FDG uptake in the affected ileal loop, hypermetabolic abdominal and mediastinal lymphadenopathies, and multiple hypermetabolic bone lesions. Iliac crest osteo-medullary biopsy revealed bone marrow infiltration by "signet ring" cells with intestinal differentiation. Double-balloon enteroscopy was used to obtain biopsies that confirmed the ileal origin of the PSRCC.


Assuntos
Carcinoma de Células em Anel de Sinete/diagnóstico , Doença de Crohn/complicações , Neoplasias do Íleo/diagnóstico , Biópsia , Carcinoma de Células em Anel de Sinete/complicações , Carcinoma de Células em Anel de Sinete/patologia , Depsipeptídeos , Fluordesoxiglucose F18 , Fusarium , Humanos , Neoplasias do Íleo/complicações , Neoplasias do Íleo/patologia , Pessoa de Meia-Idade , Imagem Multimodal , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X
11.
Eur J Radiol ; 82(1): e1-e10, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22999647

RESUMO

OBJECTIVES: The major objective was to prospectively compare the grade of bowel distension obtained with four different computed tomography (CT) techniques dedicated for the examination of the small intestine (CT enteroclysis [CTE] and enterography [CTe]), of the colon (CT with water enema [CT-WE]), or both (CTe with water enema [CTe-WE]). The secondary objective was to assess patients' tolerance toward each CT protocol. MATERIALS AND METHODS: Recruitment was designed to obtain four groups of the same number of patients (30). Each group corresponded to a specific CT technique, for a total of 120 consecutive outpatients (65 male and 55 female, mean age 51.09 ± 13.36 years). CTE was performed after injection of methylcellulose through a nasojejunal tube, while in the CTe protocol a polyethylene glycol electrolyte solution was orally administered to patients prior to the CT acquisition. In the CT-WE protocol intraluminal contrast (water) was administered only by a rectal enema, while CTe-WE technique included both a rectal water enema and oral ingestion of neutral contrast material to obtain a simultaneous distension of small and large bowel. CT studies were reviewed in consensus by two gastrointestinal radiologists who performed a quantitative and qualitative analysis of bowel distension on a per segment basis. The presence and type of adverse effects were recorded. RESULTS: CTE provided the best distension of jejunal loops (median diameter 27 mm, range 17-32 mm) when compared to all the other techniques (p<0.0001). The frequency of patients with an adequate distension of the terminal ileum was not significantly different among the four groups (p=0.0608). At both quantitative and qualitative analysis CT-WE and CTe-WE determined a greater and more consistent luminal filling of the large intestine than that provided by both CTE and CTe (p<0.0001 for all colonic segments). Adverse effects were more frequent in patients belonging to the CTE group (p<0.0028). CONCLUSIONS: CTE allows an optimal distension of jejunal loops, but it is the most uncomfortable CT protocol. When performing CT-WE, an adequate retrograde distension of the terminal ileum was provided in a particularly high percentage of patients. CTe-WE provides a simultaneous optimal distension of both small and large bowel.


Assuntos
Algoritmos , Sulfato de Bário , Enema/métodos , Intestinos/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...